ID

VAR-201902-0799


CVE

CVE-2019-0111


TITLE

Intel Data Center Manager SDK Vulnerable to information disclosure

Trust: 0.8

sources: JVNDB: JVNDB-2019-001833

DESCRIPTION

Improper file permissions for Intel(R) Data Center Manager SDK before version 5.0.2 may allow an authenticated user to potentially enable information disclosure via local access. A local attacker can exploit this issue to gain elevated privileges on an affected system. This product mainly provides real-time power supply and heat dissipation data of equipment

Trust: 1.98

sources: NVD: CVE-2019-0111 // JVNDB: JVNDB-2019-001833 // BID: 107067 // VULHUB: VHN-140142

AFFECTED PRODUCTS

vendor:intelmodel:data center managerscope:ltversion:5.0.2

Trust: 1.0

vendor:intelmodel:data center manager sdkscope:ltversion:5.0.2

Trust: 0.8

vendor:intelmodel:data center manager sdkscope:eqversion:0

Trust: 0.3

vendor:intelmodel:data center manager sdkscope:neversion:5.0.2

Trust: 0.3

sources: BID: 107067 // JVNDB: JVNDB-2019-001833 // NVD: CVE-2019-0111

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2019-0111
value: MEDIUM

Trust: 1.0

NVD: CVE-2019-0111
value: MEDIUM

Trust: 0.8

CNNVD: CNNVD-201902-707
value: MEDIUM

Trust: 0.6

VULHUB: VHN-140142
value: LOW

Trust: 0.1

nvd@nist.gov: CVE-2019-0111
severity: LOW
baseScore: 2.1
vectorString: AV:L/AC:L/AU:N/C:P/I:N/A:N
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: NONE
availabilityImpact: NONE
exploitabilityScore: 3.9
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.8

VULHUB: VHN-140142
severity: LOW
baseScore: 2.1
vectorString: AV:L/AC:L/AU:N/C:P/I:N/A:N
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: NONE
availabilityImpact: NONE
exploitabilityScore: 3.9
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

nvd@nist.gov: CVE-2019-0111
baseSeverity: MEDIUM
baseScore: 5.5
vectorString: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: NONE
availabilityImpact: NONE
exploitabilityScore: 1.8
impactScore: 3.6
version: 3.0

Trust: 1.8

sources: VULHUB: VHN-140142 // JVNDB: JVNDB-2019-001833 // CNNVD: CNNVD-201902-707 // NVD: CVE-2019-0111

PROBLEMTYPE DATA

problemtype:CWE-732

Trust: 1.1

problemtype:CWE-200

Trust: 0.9

sources: VULHUB: VHN-140142 // JVNDB: JVNDB-2019-001833 // NVD: CVE-2019-0111

THREAT TYPE

local

Trust: 0.9

sources: BID: 107067 // CNNVD: CNNVD-201902-707

TYPE

information disclosure

Trust: 0.6

sources: CNNVD: CNNVD-201902-707

CONFIGURATIONS

sources: JVNDB: JVNDB-2019-001833

PATCH

title:INTEL-SA-00215url:https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html

Trust: 0.8

title:Intel Data Center Manager SDK Security vulnerabilitiesurl:http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=89529

Trust: 0.6

sources: JVNDB: JVNDB-2019-001833 // CNNVD: CNNVD-201902-707

EXTERNAL IDS

db:NVDid:CVE-2019-0111

Trust: 2.8

db:ICS CERTid:ICSA-19-050-01

Trust: 2.5

db:BIDid:107067

Trust: 2.0

db:JVNDBid:JVNDB-2019-001833

Trust: 0.8

db:CNNVDid:CNNVD-201902-707

Trust: 0.7

db:NSFOCUSid:42778

Trust: 0.6

db:AUSCERTid:ESB-2019.0521

Trust: 0.6

db:VULHUBid:VHN-140142

Trust: 0.1

sources: VULHUB: VHN-140142 // BID: 107067 // JVNDB: JVNDB-2019-001833 // CNNVD: CNNVD-201902-707 // NVD: CVE-2019-0111

REFERENCES

url:https://ics-cert.us-cert.gov/advisories/icsa-19-050-01

Trust: 3.1

url:http://www.securityfocus.com/bid/107067

Trust: 2.3

url:https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00215.html

Trust: 2.0

url:https://nvd.nist.gov/vuln/detail/cve-2019-0111

Trust: 1.4

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-0111

Trust: 0.8

url:https://www.auscert.org.au/bulletins/75830

Trust: 0.6

url:http://www.nsfocus.net/vulndb/42778

Trust: 0.6

url:http://www.intel.com/

Trust: 0.3

sources: VULHUB: VHN-140142 // BID: 107067 // JVNDB: JVNDB-2019-001833 // CNNVD: CNNVD-201902-707 // NVD: CVE-2019-0111

CREDITS

Intel’s Product Security Incident Response Team reported these vulnerabilities to NCCIC.,DCG Red Team.,vendor ??

Trust: 0.6

sources: CNNVD: CNNVD-201902-707

SOURCES

db:VULHUBid:VHN-140142
db:BIDid:107067
db:JVNDBid:JVNDB-2019-001833
db:CNNVDid:CNNVD-201902-707
db:NVDid:CVE-2019-0111

LAST UPDATE DATE

2024-11-23T22:00:07.038000+00:00


SOURCES UPDATE DATE

db:VULHUBid:VHN-140142date:2020-08-24T00:00:00
db:BIDid:107067date:2019-02-12T00:00:00
db:JVNDBid:JVNDB-2019-001833date:2019-03-27T00:00:00
db:CNNVDid:CNNVD-201902-707date:2020-08-25T00:00:00
db:NVDid:CVE-2019-0111date:2024-11-21T04:16:15.050

SOURCES RELEASE DATE

db:VULHUBid:VHN-140142date:2019-02-18T00:00:00
db:BIDid:107067date:2019-02-12T00:00:00
db:JVNDBid:JVNDB-2019-001833date:2019-03-27T00:00:00
db:CNNVDid:CNNVD-201902-707date:2019-02-18T00:00:00
db:NVDid:CVE-2019-0111date:2019-02-18T17:29:00.830