DESCRIPTION

Improper flow control in crypto routines for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable a denial of service via local access. Intel(R) Data Center Manager SDK Contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. A local attacker can exploit this issue to crash the operating system, denying service to legitimate users. This product mainly provides real-time power supply and heat dissipation data of equipment

Trust: 1.98

sources: NVD: CVE-2019-0112 // JVNDB: JVNDB-2019-001834 // BID: 107064 // VULHUB: VHN-140143

AFFECTED PRODUCTS

vendor:intelmodel:data center managerscope:ltversion:5.0.2

Trust: 1.0

vendor:intelmodel:data center manager sdkscope:ltversion:5.0.2

Trust: 0.8

vendor:intelmodel:data center manager sdkscope:eqversion:0

Trust: 0.3

vendor:intelmodel:data center manager sdkscope:neversion:5.0.2

Trust: 0.3

sources: BID: 107064 // JVNDB: JVNDB-2019-001834 // NVD: CVE-2019-0112

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2019-0112
value: MEDIUM

Trust: 1.0

NVD: CVE-2019-0112
value: MEDIUM

Trust: 0.8

CNNVD: CNNVD-201902-705
value: MEDIUM

Trust: 0.6

VULHUB: VHN-140143
value: LOW

Trust: 0.1

nvd@nist.gov: CVE-2019-0112
severity: LOW
baseScore: 2.1
vectorString: AV:L/AC:L/AU:N/C:N/I:N/A:P
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: PARTIAL
exploitabilityScore: 3.9
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.8

VULHUB: VHN-140143
severity: LOW
baseScore: 2.1
vectorString: AV:L/AC:L/AU:N/C:N/I:N/A:P
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: PARTIAL
exploitabilityScore: 3.9
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

nvd@nist.gov: CVE-2019-0112
baseSeverity: MEDIUM
baseScore: 4.4
vectorString: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: HIGH
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: 0.8
impactScore: 3.6
version: 3.0

Trust: 1.8

sources: VULHUB: VHN-140143 // JVNDB: JVNDB-2019-001834 // CNNVD: CNNVD-201902-705 // NVD: CVE-2019-0112

PROBLEMTYPE DATA

problemtype:NVD-CWE-noinfo

Trust: 1.0

problemtype:CWE-20

Trust: 0.9

sources: VULHUB: VHN-140143 // JVNDB: JVNDB-2019-001834 // NVD: CVE-2019-0112

THREAT TYPE

local

Trust: 0.9

sources: BID: 107064 // CNNVD: CNNVD-201902-705

TYPE

input validation error

Trust: 0.6

sources: CNNVD: CNNVD-201902-705

CONFIGURATIONS

sources: JVNDB: JVNDB-2019-001834

PATCH

title:INTEL-SA-00215url:https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html

Trust: 0.8

title:Intel Data Center Manager SDK Security vulnerabilitiesurl:http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=89527

Trust: 0.6

sources: JVNDB: JVNDB-2019-001834 // CNNVD: CNNVD-201902-705

EXTERNAL IDS

db:NVDid:CVE-2019-0112

Trust: 2.8

db:ICS CERTid:ICSA-19-050-01

Trust: 2.5

db:BIDid:107064

Trust: 2.0

db:JVNDBid:JVNDB-2019-001834

Trust: 0.8

db:CNNVDid:CNNVD-201902-705

Trust: 0.7

db:NSFOCUSid:42780

Trust: 0.6

db:AUSCERTid:ESB-2019.0521

Trust: 0.6

db:VULHUBid:VHN-140143

Trust: 0.1

sources: VULHUB: VHN-140143 // BID: 107064 // JVNDB: JVNDB-2019-001834 // CNNVD: CNNVD-201902-705 // NVD: CVE-2019-0112

REFERENCES

url:https://ics-cert.us-cert.gov/advisories/icsa-19-050-01

Trust: 3.1

url:http://www.securityfocus.com/bid/107064

Trust: 2.3

url:https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00215.html

Trust: 2.0

url:https://nvd.nist.gov/vuln/detail/cve-2019-0112

Trust: 1.4

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-0112

Trust: 0.8

url:https://www.auscert.org.au/bulletins/75830

Trust: 0.6

url:http://www.nsfocus.net/vulndb/42780

Trust: 0.6

url:http://www.intel.com/

Trust: 0.3

sources: VULHUB: VHN-140143 // BID: 107064 // JVNDB: JVNDB-2019-001834 // CNNVD: CNNVD-201902-705 // NVD: CVE-2019-0112

CREDITS

Intel’s Product Security Incident Response Team reported these vulnerabilities to NCCIC.,vendor   ,DCG Red Team

Trust: 0.6

sources: CNNVD: CNNVD-201902-705

SOURCES

db:VULHUBid:VHN-140143
db:BIDid:107064
db:JVNDBid:JVNDB-2019-001834
db:CNNVDid:CNNVD-201902-705
db:NVDid:CVE-2019-0112

LAST UPDATE DATE

2024-11-23T22:00:06.971000+00:00


SOURCES UPDATE DATE

db:VULHUBid:VHN-140143date:2019-02-28T00:00:00
db:BIDid:107064date:2019-02-12T00:00:00
db:JVNDBid:JVNDB-2019-001834date:2019-03-27T00:00:00
db:CNNVDid:CNNVD-201902-705date:2021-07-26T00:00:00
db:NVDid:CVE-2019-0112date:2024-11-21T04:16:15.160

SOURCES RELEASE DATE

db:VULHUBid:VHN-140143date:2019-02-18T00:00:00
db:BIDid:107064date:2019-02-12T00:00:00
db:JVNDBid:JVNDB-2019-001834date:2019-03-27T00:00:00
db:CNNVDid:CNNVD-201902-705date:2019-02-18T00:00:00
db:NVDid:CVE-2019-0112date:2019-02-18T17:29:00.877