ID

VAR-202202-1734


CVE

CVE-2021-46265


TITLE

Tenda AC  series router  AC11  Out-of-bounds write vulnerability in

Trust: 0.8

sources: JVNDB: JVNDB-2022-004959

DESCRIPTION

Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. Tenda AC series router AC11 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC11 is a router from the Chinese company Tenda

Trust: 2.16

sources: NVD: CVE-2021-46265 // JVNDB: JVNDB-2022-004959 // CNVD: CNVD-2022-15165

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2022-15165

AFFECTED PRODUCTS

vendor:tendamodel:ac11scope:eqversion:02.03.01.104_cn

Trust: 1.0

vendor:tendamodel:ac11scope:eqversion:ac11 firmware 02.03.01.104_cn

Trust: 0.8

vendor:tendamodel:ac11scope:eqversion: -

Trust: 0.8

vendor:tendamodel:ac series router ac11 v02.03.01.104 cnscope: - version: -

Trust: 0.6

sources: CNVD: CNVD-2022-15165 // JVNDB: JVNDB-2022-004959 // NVD: CVE-2021-46265

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2021-46265
value: CRITICAL

Trust: 1.0

NVD: CVE-2021-46265
value: CRITICAL

Trust: 0.8

CNVD: CNVD-2022-15165
value: HIGH

Trust: 0.6

CNNVD: CNNVD-202202-1301
value: CRITICAL

Trust: 0.6

nvd@nist.gov: CVE-2021-46265
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.8

CNVD: CNVD-2022-15165
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

nvd@nist.gov: CVE-2021-46265
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

NVD: CVE-2021-46265
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2022-15165 // JVNDB: JVNDB-2022-004959 // CNNVD: CNNVD-202202-1301 // NVD: CVE-2021-46265

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2022-004959 // NVD: CVE-2021-46265

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-202202-1301

TYPE

buffer error

Trust: 0.6

sources: CNNVD: CNNVD-202202-1301

PATCH

title:Top Pageurl:https://www.tendacn.com/default.html

Trust: 0.8

title:Patch for Tenda AC Series Router Buffer Overflow Vulnerability (CNVD-2022-15165)url:https://www.cnvd.org.cn/patchInfo/show/322286

Trust: 0.6

sources: CNVD: CNVD-2022-15165 // JVNDB: JVNDB-2022-004959

EXTERNAL IDS

db:NVDid:CVE-2021-46265

Trust: 3.8

db:JVNDBid:JVNDB-2022-004959

Trust: 0.8

db:CNVDid:CNVD-2022-15165

Trust: 0.6

db:CNNVDid:CNNVD-202202-1301

Trust: 0.6

sources: CNVD: CNVD-2022-15165 // JVNDB: JVNDB-2022-004959 // CNNVD: CNNVD-202202-1301 // NVD: CVE-2021-46265

REFERENCES

url:https://github.com/ainevsia/cve-request/tree/main/tenda/13

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2021-46265

Trust: 2.0

sources: CNVD: CNVD-2022-15165 // JVNDB: JVNDB-2022-004959 // CNNVD: CNNVD-202202-1301 // NVD: CVE-2021-46265

SOURCES

db:CNVDid:CNVD-2022-15165
db:JVNDBid:JVNDB-2022-004959
db:CNNVDid:CNNVD-202202-1301
db:NVDid:CVE-2021-46265

LAST UPDATE DATE

2024-11-23T22:24:58.268000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2022-15165date:2022-02-27T00:00:00
db:JVNDBid:JVNDB-2022-004959date:2023-05-12T03:35:00
db:CNNVDid:CNNVD-202202-1301date:2022-03-10T00:00:00
db:NVDid:CVE-2021-46265date:2024-11-21T06:33:50.343

SOURCES RELEASE DATE

db:CNVDid:CNVD-2022-15165date:2022-02-27T00:00:00
db:JVNDBid:JVNDB-2022-004959date:2023-05-12T00:00:00
db:CNNVDid:CNNVD-202202-1301date:2022-02-15T00:00:00
db:NVDid:CVE-2021-46265date:2022-02-15T20:15:07.707