ID

VAR-202205-1985


CVE

CVE-2022-30474


TITLE

Tenda AC Series Router Buffer error vulnerability

Trust: 0.6

sources: CNNVD: CNNVD-202205-4195

DESCRIPTION

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request

Trust: 0.99

sources: NVD: CVE-2022-30474 // VULMON: CVE-2022-30474

AFFECTED PRODUCTS

vendor:tendamodel:ac18scope:eqversion:15.03.05.19\(6318\)

Trust: 1.0

sources: NVD: CVE-2022-30474

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2022-30474
value: CRITICAL

Trust: 1.0

CNNVD: CNNVD-202205-4195
value: CRITICAL

Trust: 0.6

VULMON: CVE-2022-30474
value: HIGH

Trust: 0.1

nvd@nist.gov: CVE-2022-30474
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.1

nvd@nist.gov: CVE-2022-30474
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

sources: VULMON: CVE-2022-30474 // CNNVD: CNNVD-202205-4195 // NVD: CVE-2022-30474

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

sources: NVD: CVE-2022-30474

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-202205-4195

TYPE

buffer error

Trust: 0.6

sources: CNNVD: CNNVD-202205-4195

PATCH

title: - url:https://github.com/lcyfrank/VulnRepo

Trust: 0.1

sources: VULMON: CVE-2022-30474

EXTERNAL IDS

db:NVDid:CVE-2022-30474

Trust: 1.7

db:CS-HELPid:SB2022052708

Trust: 0.6

db:CNNVDid:CNNVD-202205-4195

Trust: 0.6

db:VULMONid:CVE-2022-30474

Trust: 0.1

sources: VULMON: CVE-2022-30474 // CNNVD: CNNVD-202205-4195 // NVD: CVE-2022-30474

REFERENCES

url:https://github.com/lcyfrank/vulnrepo/tree/master/iot/tenda/5

Trust: 1.7

url:https://www.cybersecurity-help.cz/vdb/sb2022052708

Trust: 0.6

url:https://cxsecurity.com/cveshow/cve-2022-30474/

Trust: 0.6

url:https://cwe.mitre.org/data/definitions/787.html

Trust: 0.1

url:https://nvd.nist.gov

Trust: 0.1

url:https://github.com/lcyfrank/vulnrepo

Trust: 0.1

sources: VULMON: CVE-2022-30474 // CNNVD: CNNVD-202205-4195 // NVD: CVE-2022-30474

SOURCES

db:VULMONid:CVE-2022-30474
db:CNNVDid:CNNVD-202205-4195
db:NVDid:CVE-2022-30474

LAST UPDATE DATE

2024-11-23T22:10:45.314000+00:00


SOURCES UPDATE DATE

db:VULMONid:CVE-2022-30474date:2022-06-03T00:00:00
db:CNNVDid:CNNVD-202205-4195date:2022-06-06T00:00:00
db:NVDid:CVE-2022-30474date:2024-11-21T07:02:48.753

SOURCES RELEASE DATE

db:VULMONid:CVE-2022-30474date:2022-05-26T00:00:00
db:CNNVDid:CNNVD-202205-4195date:2022-05-26T00:00:00
db:NVDid:CVE-2022-30474date:2022-05-26T16:15:08.533