ID

VAR-202208-2223


CVE

CVE-2022-37125


TITLE

D-Link Systems, Inc.  of  DIR-816  Command injection vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2022-016411

DESCRIPTION

D-link DIR-816 A2_v1.10CNB04.img is vulnerable to Command injection via /goform/NTPSyncWithHost. D-Link Systems, Inc. of DIR-816 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Trust: 1.71

sources: NVD: CVE-2022-37125 // JVNDB: JVNDB-2022-016411 // VULMON: CVE-2022-37125

AFFECTED PRODUCTS

vendor:dlinkmodel:dir-816scope:eqversion:1.10cnb04

Trust: 1.0

vendor:d linkmodel:dir-816scope:eqversion: -

Trust: 0.8

vendor:d linkmodel:dir-816scope:eqversion:dir-816 firmware 1.10cnb04

Trust: 0.8

vendor:d linkmodel:dir-816scope: - version: -

Trust: 0.8

sources: JVNDB: JVNDB-2022-016411 // NVD: CVE-2022-37125

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2022-37125
value: CRITICAL

Trust: 1.0

NVD: CVE-2022-37125
value: CRITICAL

Trust: 0.8

CNNVD: CNNVD-202208-4533
value: CRITICAL

Trust: 0.6

nvd@nist.gov: CVE-2022-37125
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

NVD: CVE-2022-37125
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: JVNDB: JVNDB-2022-016411 // CNNVD: CNNVD-202208-4533 // NVD: CVE-2022-37125

PROBLEMTYPE DATA

problemtype:CWE-77

Trust: 1.0

problemtype:Command injection (CWE-77) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2022-016411 // NVD: CVE-2022-37125

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-202208-4533

TYPE

command injection

Trust: 0.6

sources: CNNVD: CNNVD-202208-4533

EXTERNAL IDS

db:NVDid:CVE-2022-37125

Trust: 3.3

db:JVNDBid:JVNDB-2022-016411

Trust: 0.8

db:CNNVDid:CNNVD-202208-4533

Trust: 0.6

db:VULMONid:CVE-2022-37125

Trust: 0.1

sources: VULMON: CVE-2022-37125 // JVNDB: JVNDB-2022-016411 // CNNVD: CNNVD-202208-4533 // NVD: CVE-2022-37125

REFERENCES

url:https://www.dlink.com/en/security-bulletin/

Trust: 2.5

url:https://github.com/z1r00/iot_vul/tree/main/dlink/dir816/form2systime_cgi

Trust: 2.5

url:https://nvd.nist.gov/vuln/detail/cve-2022-37125

Trust: 0.8

url:https://cxsecurity.com/cveshow/cve-2022-37125/

Trust: 0.6

url:https://nvd.nist.gov

Trust: 0.1

sources: VULMON: CVE-2022-37125 // JVNDB: JVNDB-2022-016411 // CNNVD: CNNVD-202208-4533 // NVD: CVE-2022-37125

SOURCES

db:VULMONid:CVE-2022-37125
db:JVNDBid:JVNDB-2022-016411
db:CNNVDid:CNNVD-202208-4533
db:NVDid:CVE-2022-37125

LAST UPDATE DATE

2024-08-14T14:55:17.458000+00:00


SOURCES UPDATE DATE

db:VULMONid:CVE-2022-37125date:2022-09-01T00:00:00
db:JVNDBid:JVNDB-2022-016411date:2023-10-04T08:57:00
db:CNNVDid:CNNVD-202208-4533date:2022-09-13T00:00:00
db:NVDid:CVE-2022-37125date:2022-09-09T14:16:48.287

SOURCES RELEASE DATE

db:VULMONid:CVE-2022-37125date:2022-08-31T00:00:00
db:JVNDBid:JVNDB-2022-016411date:2023-10-04T00:00:00
db:CNNVDid:CNNVD-202208-4533date:2022-08-31T00:00:00
db:NVDid:CVE-2022-37125date:2022-08-31T22:15:08.527