ID

VAR-202212-0072


CVE

CVE-2022-45663


TITLE

Tenda i22 formWifiMacFilterSet function buffer overflow vulnerability

Trust: 0.6

sources: CNVD: CNVD-2023-13083

DESCRIPTION

Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

Trust: 1.53

sources: NVD: CVE-2022-45663 // CNVD: CNVD-2023-13083 // VULMON: CVE-2022-45663

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2023-13083

AFFECTED PRODUCTS

vendor:tendamodel:i22scope:eqversion:1.0.0.3\(4687\)

Trust: 1.0

vendor:tendamodel:i22scope:eqversion:v1.0.0.3(4687)

Trust: 0.6

sources: CNVD: CNVD-2023-13083 // NVD: CVE-2022-45663

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2022-45663
value: HIGH

Trust: 1.0

CNVD: CNVD-2023-13083
value: HIGH

Trust: 0.6

CNNVD: CNNVD-202212-1880
value: HIGH

Trust: 0.6

CNVD: CNVD-2023-13083
severity: HIGH
baseScore: 7.8
vectorString: AV:N/AC:L/AU:N/C:N/I:N/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 6.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

nvd@nist.gov: CVE-2022-45663
baseSeverity: HIGH
baseScore: 7.5
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 3.6
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2023-13083 // CNNVD: CNNVD-202212-1880 // NVD: CVE-2022-45663

PROBLEMTYPE DATA

problemtype:CWE-120

Trust: 1.0

sources: NVD: CVE-2022-45663

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-202212-1880

TYPE

other

Trust: 0.6

sources: CNNVD: CNNVD-202212-1880

EXTERNAL IDS

db:NVDid:CVE-2022-45663

Trust: 2.3

db:CNVDid:CNVD-2023-13083

Trust: 0.6

db:CNNVDid:CNNVD-202212-1880

Trust: 0.6

db:VULMONid:CVE-2022-45663

Trust: 0.1

sources: CNVD: CNVD-2023-13083 // VULMON: CVE-2022-45663 // CNNVD: CNNVD-202212-1880 // NVD: CVE-2022-45663

REFERENCES

url:https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formwifimacfilterset/formwifimacfilterset.md

Trust: 1.7

url:https://nvd.nist.gov/vuln/detail/cve-2022-45663

Trust: 0.6

url:https://cxsecurity.com/cveshow/cve-2022-45663/

Trust: 0.6

url:https://nvd.nist.gov

Trust: 0.1

sources: CNVD: CNVD-2023-13083 // VULMON: CVE-2022-45663 // CNNVD: CNNVD-202212-1880 // NVD: CVE-2022-45663

SOURCES

db:CNVDid:CNVD-2023-13083
db:VULMONid:CVE-2022-45663
db:CNNVDid:CNNVD-202212-1880
db:NVDid:CVE-2022-45663

LAST UPDATE DATE

2024-08-14T13:21:26.157000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2023-13083date:2023-03-01T00:00:00
db:VULMONid:CVE-2022-45663date:2022-12-02T00:00:00
db:CNNVDid:CNNVD-202212-1880date:2022-12-06T00:00:00
db:NVDid:CVE-2022-45663date:2022-12-06T00:42:26.173

SOURCES RELEASE DATE

db:CNVDid:CNVD-2023-13083date:2023-03-01T00:00:00
db:VULMONid:CVE-2022-45663date:2022-12-02T00:00:00
db:CNNVDid:CNNVD-202212-1880date:2022-12-02T00:00:00
db:NVDid:CVE-2022-45663date:2022-12-02T18:15:12.080