DESCRIPTION

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19810). Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure

Trust: 2.34

sources: NVD: CVE-2023-24988 // JVNDB: JVNDB-2023-004018 // ZDI: ZDI-23-196 // VULMON: CVE-2023-24988

AFFECTED PRODUCTS

vendor:siemensmodel:tecnomatix plant simulationscope:ltversion:2201.0006

Trust: 1.0

vendor:シーメンスmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion:2201.0006

Trust: 0.8

vendor:siemensmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.7

sources: ZDI: ZDI-23-196 // JVNDB: JVNDB-2023-004018 // NVD: CVE-2023-24988

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2023-24988
value: HIGH

Trust: 1.0

productcert@siemens.com: CVE-2023-24988
value: HIGH

Trust: 1.0

NVD: CVE-2023-24988
value: HIGH

Trust: 0.8

ZDI: CVE-2023-24988
value: HIGH

Trust: 0.7

CNNVD: CNNVD-202302-1049
value: HIGH

Trust: 0.6

nvd@nist.gov: CVE-2023-24988
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 2.0

NVD: CVE-2023-24988
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

ZDI: CVE-2023-24988
baseSeverity: HIGH
baseScore: 7.8
vectorString: AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-23-196 // JVNDB: JVNDB-2023-004018 // CNNVD: CNNVD-202302-1049 // NVD: CVE-2023-24988 // NVD: CVE-2023-24988

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2023-004018 // NVD: CVE-2023-24988

THREAT TYPE

local

Trust: 0.6

sources: CNNVD: CNNVD-202302-1049

TYPE

buffer error

Trust: 0.6

sources: CNNVD: CNNVD-202302-1049

PATCH

title:Siemens has issued an update to correct this vulnerability.url:https://cert-portal.siemens.com/productcert/html/ssa-847261.html

Trust: 0.7

title:Tecnomatix Plant Simulation Buffer error vulnerability fixurl:http://123.124.177.30/web/xxk/bdxqById.tag?id=226461

Trust: 0.6

sources: ZDI: ZDI-23-196 // CNNVD: CNNVD-202302-1049

EXTERNAL IDS

db:NVDid:CVE-2023-24988

Trust: 4.0

db:SIEMENSid:SSA-847261

Trust: 2.5

db:JVNid:JVNVU97514209

Trust: 0.8

db:JVNDBid:JVNDB-2023-004018

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-19810

Trust: 0.7

db:ZDIid:ZDI-23-196

Trust: 0.7

db:CNNVDid:CNNVD-202302-1049

Trust: 0.6

db:VULMONid:CVE-2023-24988

Trust: 0.1

sources: ZDI: ZDI-23-196 // VULMON: CVE-2023-24988 // JVNDB: JVNDB-2023-004018 // CNNVD: CNNVD-202302-1049 // NVD: CVE-2023-24988

REFERENCES

url:https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf

Trust: 2.5

url:https://jvn.jp/vu/jvnvu97514209/

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2023-24988

Trust: 0.8

url:https://cert-portal.siemens.com/productcert/html/ssa-847261.html

Trust: 0.7

url:https://cxsecurity.com/cveshow/cve-2023-24988/

Trust: 0.6

url:https://cwe.mitre.org/data/definitions/787.html

Trust: 0.1

url:https://nvd.nist.gov

Trust: 0.1

sources: ZDI: ZDI-23-196 // VULMON: CVE-2023-24988 // JVNDB: JVNDB-2023-004018 // CNNVD: CNNVD-202302-1049 // NVD: CVE-2023-24988

CREDITS

Simon Janz (@esj4y)

Trust: 0.7

sources: ZDI: ZDI-23-196

SOURCES

db:ZDIid:ZDI-23-196
db:VULMONid:CVE-2023-24988
db:JVNDBid:JVNDB-2023-004018
db:CNNVDid:CNNVD-202302-1049
db:NVDid:CVE-2023-24988

LAST UPDATE DATE

2024-08-14T12:44:47.745000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-23-196date:2023-02-24T00:00:00
db:VULMONid:CVE-2023-24988date:2023-02-14T00:00:00
db:JVNDBid:JVNDB-2023-004018date:2023-10-25T06:41:00
db:CNNVDid:CNNVD-202302-1049date:2023-02-23T00:00:00
db:NVDid:CVE-2023-24988date:2023-02-22T20:25:42.120

SOURCES RELEASE DATE

db:ZDIid:ZDI-23-196date:2023-02-24T00:00:00
db:VULMONid:CVE-2023-24988date:2023-02-14T00:00:00
db:JVNDBid:JVNDB-2023-004018date:2023-10-25T00:00:00
db:CNNVDid:CNNVD-202302-1049date:2023-02-14T00:00:00
db:NVDid:CVE-2023-24988date:2023-02-14T11:15:17.253