ID

VAR-202307-1134


CVE

CVE-2023-37710


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  AC10  firmware and  ac1206  Out-of-bounds write vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2023-019246

DESCRIPTION

Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Trust: 1.62

sources: NVD: CVE-2023-37710 // JVNDB: JVNDB-2023-019246

AFFECTED PRODUCTS

vendor:tendamodel:ac10scope:eqversion:15.03.06.47

Trust: 1.0

vendor:tendamodel:ac1206scope:eqversion:15.03.06.23

Trust: 1.0

vendor:tendamodel:ac1206scope: - version: -

Trust: 0.8

vendor:tendamodel:ac10scope: - version: -

Trust: 0.8

sources: JVNDB: JVNDB-2023-019246 // NVD: CVE-2023-37710

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2023-37710
value: CRITICAL

Trust: 1.0

NVD: CVE-2023-37710
value: CRITICAL

Trust: 0.8

CNNVD: CNNVD-202307-530
value: CRITICAL

Trust: 0.6

nvd@nist.gov: CVE-2023-37710
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

NVD: CVE-2023-37710
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: JVNDB: JVNDB-2023-019246 // CNNVD: CNNVD-202307-530 // NVD: CVE-2023-37710

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2023-019246 // NVD: CVE-2023-37710

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-202307-530

TYPE

buffer error

Trust: 0.6

sources: CNNVD: CNNVD-202307-530

PATCH

title:Tenda AC1206 Buffer error vulnerability fixurl:http://123.124.177.30/web/xxk/bdxqById.tag?id=246055

Trust: 0.6

sources: CNNVD: CNNVD-202307-530

EXTERNAL IDS

db:NVDid:CVE-2023-37710

Trust: 3.2

db:JVNDBid:JVNDB-2023-019246

Trust: 0.8

db:CNNVDid:CNNVD-202307-530

Trust: 0.6

sources: JVNDB: JVNDB-2023-019246 // CNNVD: CNNVD-202307-530 // NVD: CVE-2023-37710

REFERENCES

url:https://github.com/firmrec/iot-vulns/tree/main/tenda/fromsetwirelessrepeat

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2023-37710

Trust: 0.8

url:https://cxsecurity.com/cveshow/cve-2023-37710/

Trust: 0.6

sources: JVNDB: JVNDB-2023-019246 // CNNVD: CNNVD-202307-530 // NVD: CVE-2023-37710

SOURCES

db:JVNDBid:JVNDB-2023-019246
db:CNNVDid:CNNVD-202307-530
db:NVDid:CVE-2023-37710

LAST UPDATE DATE

2024-08-14T15:05:34.334000+00:00


SOURCES UPDATE DATE

db:JVNDBid:JVNDB-2023-019246date:2024-01-12T08:04:00
db:CNNVDid:CNNVD-202307-530date:2023-07-14T00:00:00
db:NVDid:CVE-2023-37710date:2023-07-13T19:47:08.147

SOURCES RELEASE DATE

db:JVNDBid:JVNDB-2023-019246date:2024-01-12T00:00:00
db:CNNVDid:CNNVD-202307-530date:2023-07-10T00:00:00
db:NVDid:CVE-2023-37710date:2023-07-10T17:15:09.797