ID

VAR-202308-0240


CVE

CVE-2023-38524


DESCRIPTION

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

Trust: 1.0

sources: NVD: CVE-2023-38524

AFFECTED PRODUCTS

vendor:siemensmodel:teamcenter visualizationscope:ltversion:14.2.0.6

Trust: 1.0

vendor:siemensmodel:parasolidscope:ltversion:34.1.258

Trust: 1.0

vendor:siemensmodel:parasolidscope:ltversion:35.0.254

Trust: 1.0

vendor:siemensmodel:parasolidscope:ltversion:35.1.171

Trust: 1.0

vendor:siemensmodel:teamcenter visualizationscope:gteversion:14.2

Trust: 1.0

vendor:siemensmodel:parasolidscope:gteversion:34.1

Trust: 1.0

vendor:siemensmodel:parasolidscope:gteversion:35.0

Trust: 1.0

vendor:siemensmodel:teamcenter visualizationscope:gteversion:14.3

Trust: 1.0

vendor:siemensmodel:teamcenter visualizationscope:gteversion:14.1

Trust: 1.0

vendor:siemensmodel:teamcenter visualizationscope:ltversion:14.3.0.3

Trust: 1.0

vendor:siemensmodel:teamcenter visualizationscope:ltversion:14.1.0.11

Trust: 1.0

vendor:siemensmodel:parasolidscope:gteversion:35.1

Trust: 1.0

sources: NVD: CVE-2023-38524

CVSS

SEVERITY

CVSSV2

CVSSV3

NVD: CVE-2023-38524
value: HIGH

Trust: 1.0

productcert@siemens.com: CVE-2023-38524
value: LOW

Trust: 1.0

NVD:
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 1.0

productcert@siemens.com:
baseSeverity: LOW
baseScore: 3.3
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: LOW
exploitabilityScore: 1.8
impactScore: 1.4
version: 3.1

Trust: 1.0

sources: NVD: CVE-2023-38524 // NVD: CVE-2023-38524

PROBLEMTYPE DATA

problemtype:CWE-476

Trust: 1.0

sources: NVD: CVE-2023-38524

CONFIGURATIONS

sources: NVD: CVE-2023-38524

EXTERNAL IDS

db:SIEMENSid:SSA-407785

Trust: 1.0

db:NVDid:CVE-2023-38524

Trust: 1.0

sources: NVD: CVE-2023-38524

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-407785.html

Trust: 1.0

url:https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf

Trust: 1.0

sources: NVD: CVE-2023-38524

SOURCES

db:NVDid:CVE-2023-38524

LAST UPDATE DATE

2024-06-11T21:49:47.580000+00:00


SOURCES UPDATE DATE

db:NVDid:CVE-2023-38524date:2024-06-11T12:15:10.860

SOURCES RELEASE DATE

db:NVDid:CVE-2023-38524date:2023-08-08T10:15:15.627