ID

VAR-202312-0480


CVE

CVE-2023-49411


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  w30e  Out-of-bounds write vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2023-018804

DESCRIPTION

Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formDeleteMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack

Trust: 2.16

sources: NVD: CVE-2023-49411 // JVNDB: JVNDB-2023-018804 // CNVD: CNVD-2023-98053

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2023-98053

AFFECTED PRODUCTS

vendor:tendamodel:w30escope:eqversion:16.01.0.12\(4843\)

Trust: 1.0

vendor:tendamodel:w30escope:eqversion:w30e firmware 16.01.0.12(4843)

Trust: 0.8

vendor:tendamodel:w30escope: - version: -

Trust: 0.8

vendor:tendamodel:w30escope:eqversion: -

Trust: 0.8

vendor:tendamodel:w30escope:eqversion:v16.01.0.12(4843)

Trust: 0.6

sources: CNVD: CNVD-2023-98053 // JVNDB: JVNDB-2023-018804 // NVD: CVE-2023-49411

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2023-49411
value: CRITICAL

Trust: 1.0

NVD: CVE-2023-49411
value: CRITICAL

Trust: 0.8

CNVD: CNVD-2023-98053
value: HIGH

Trust: 0.6

CNVD: CNVD-2023-98053
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

nvd@nist.gov: CVE-2023-49411
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

NVD: CVE-2023-49411
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2023-98053 // JVNDB: JVNDB-2023-018804 // NVD: CVE-2023-49411

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2023-018804 // NVD: CVE-2023-49411

EXTERNAL IDS

db:NVDid:CVE-2023-49411

Trust: 3.2

db:JVNDBid:JVNDB-2023-018804

Trust: 0.8

db:CNVDid:CNVD-2023-98053

Trust: 0.6

sources: CNVD: CNVD-2023-98053 // JVNDB: JVNDB-2023-018804 // NVD: CVE-2023-49411

REFERENCES

url:https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_deletemesh/w30e_deletemesh.md

Trust: 1.8

url:https://nvd.nist.gov/vuln/detail/cve-2023-49411

Trust: 1.4

sources: CNVD: CNVD-2023-98053 // JVNDB: JVNDB-2023-018804 // NVD: CVE-2023-49411

SOURCES

db:CNVDid:CNVD-2023-98053
db:JVNDBid:JVNDB-2023-018804
db:NVDid:CVE-2023-49411

LAST UPDATE DATE

2024-08-14T15:05:20.948000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2023-98053date:2023-12-15T00:00:00
db:JVNDBid:JVNDB-2023-018804date:2024-01-12T01:18:00
db:NVDid:CVE-2023-49411date:2023-12-09T04:44:46.703

SOURCES RELEASE DATE

db:CNVDid:CNVD-2023-98053date:2023-12-15T00:00:00
db:JVNDBid:JVNDB-2023-018804date:2024-01-12T00:00:00
db:NVDid:CVE-2023-49411date:2023-12-07T18:15:08.400