ID

VAR-202402-1319


CVE

CVE-2024-23795


TITLE

Siemens'  Tecnomatix Plant Simulation  Out-of-bounds write vulnerability in

Trust: 0.8

sources: JVNDB: JVNDB-2024-002575

DESCRIPTION

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files

Trust: 2.25

sources: NVD: CVE-2024-23795 // JVNDB: JVNDB-2024-002575 // ZDI: ZDI-24-172

AFFECTED PRODUCTS

vendor:siemensmodel:tecnomatix plant simulationscope:ltversion:2302.0006

Trust: 1.0

vendor:siemensmodel:tecnomatix plant simulationscope:gteversion:2302.0

Trust: 1.0

vendor:siemensmodel:tecnomatix plant simulationscope:ltversion:2201.0012

Trust: 1.0

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion:2201.0012

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion:2302.0 that's all 2302.0006

Trust: 0.8

vendor:siemensmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.7

sources: ZDI: ZDI-24-172 // JVNDB: JVNDB-2024-002575 // NVD: CVE-2024-23795

CVSS

SEVERITY

CVSSV2

CVSSV3

productcert@siemens.com: CVE-2024-23795
value: HIGH

Trust: 1.0

OTHER: JVNDB-2024-002575
value: HIGH

Trust: 0.8

ZDI: CVE-2024-23795
value: CRITICAL

Trust: 0.7

productcert@siemens.com: CVE-2024-23795
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-002575
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

ZDI: CVE-2024-23795
baseSeverity: CRITICAL
baseScore: 7.0
vectorString: AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.0
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-24-172 // JVNDB: JVNDB-2024-002575 // NVD: CVE-2024-23795

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-002575 // NVD: CVE-2024-23795

PATCH

title:Siemens has issued an update to correct this vulnerability.url:https://cert-portal.siemens.com/productcert/html/ssa-017796.html

Trust: 0.7

sources: ZDI: ZDI-24-172

EXTERNAL IDS

db:NVDid:CVE-2024-23795

Trust: 3.3

db:SIEMENSid:SSA-017796

Trust: 1.8

db:JVNid:JVNVU91198149

Trust: 0.8

db:ICS CERTid:ICSA-24-046-07

Trust: 0.8

db:JVNDBid:JVNDB-2024-002575

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-22758

Trust: 0.7

db:ZDIid:ZDI-24-172

Trust: 0.7

sources: ZDI: ZDI-24-172 // JVNDB: JVNDB-2024-002575 // NVD: CVE-2024-23795

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-017796.html

Trust: 2.5

url:https://jvn.jp/vu/jvnvu91198149/

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2024-23795

Trust: 0.8

url:https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-07

Trust: 0.8

sources: ZDI: ZDI-24-172 // JVNDB: JVNDB-2024-002575 // NVD: CVE-2024-23795

CREDITS

Anonymous

Trust: 0.7

sources: ZDI: ZDI-24-172

SOURCES

db:ZDIid:ZDI-24-172
db:JVNDBid:JVNDB-2024-002575
db:NVDid:CVE-2024-23795

LAST UPDATE DATE

2024-08-14T12:19:27.427000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-24-172date:2024-07-01T00:00:00
db:JVNDBid:JVNDB-2024-002575date:2024-02-19T07:07:00
db:NVDid:CVE-2024-23795date:2024-02-13T19:21:23.593

SOURCES RELEASE DATE

db:ZDIid:ZDI-24-172date:2024-02-15T00:00:00
db:JVNDBid:JVNDB-2024-002575date:2024-02-15T00:00:00
db:NVDid:CVE-2024-23795date:2024-02-13T09:15:47.550