ID

VAR-202402-1323


CVE

CVE-2024-23796


TITLE

Siemens'  Tecnomatix Plant Simulation  Out-of-bounds write vulnerability in

Trust: 0.8

sources: JVNDB: JVNDB-2024-002576

DESCRIPTION

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer

Trust: 2.25

sources: NVD: CVE-2024-23796 // JVNDB: JVNDB-2024-002576 // ZDI: ZDI-24-173

AFFECTED PRODUCTS

vendor:siemensmodel:tecnomatix plant simulationscope:ltversion:2302.0006

Trust: 1.0

vendor:siemensmodel:tecnomatix plant simulationscope:gteversion:2302.0

Trust: 1.0

vendor:siemensmodel:tecnomatix plant simulationscope:ltversion:2201.0012

Trust: 1.0

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion:2201.0012

Trust: 0.8

vendor:シーメンスmodel:tecnomatix plant simulationscope:eqversion:2302.0 that's all 2302.0006

Trust: 0.8

vendor:siemensmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.7

sources: ZDI: ZDI-24-173 // JVNDB: JVNDB-2024-002576 // NVD: CVE-2024-23796

CVSS

SEVERITY

CVSSV2

CVSSV3

productcert@siemens.com: CVE-2024-23796
value: HIGH

Trust: 1.0

OTHER: JVNDB-2024-002576
value: HIGH

Trust: 0.8

ZDI: CVE-2024-23796
value: HIGH

Trust: 0.7

productcert@siemens.com: CVE-2024-23796
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-002576
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

ZDI: CVE-2024-23796
baseSeverity: HIGH
baseScore: 7.8
vectorString: AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-24-173 // JVNDB: JVNDB-2024-002576 // NVD: CVE-2024-23796

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:CWE-122

Trust: 1.0

problemtype:Out-of-bounds writing (CWE-787) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-002576 // NVD: CVE-2024-23796

PATCH

title:Siemens has issued an update to correct this vulnerability.url:https://cert-portal.siemens.com/productcert/html/ssa-017796.html

Trust: 0.7

sources: ZDI: ZDI-24-173

EXTERNAL IDS

db:NVDid:CVE-2024-23796

Trust: 3.3

db:SIEMENSid:SSA-017796

Trust: 1.8

db:JVNid:JVNVU91198149

Trust: 0.8

db:ICS CERTid:ICSA-24-046-07

Trust: 0.8

db:JVNDBid:JVNDB-2024-002576

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-22759

Trust: 0.7

db:ZDIid:ZDI-24-173

Trust: 0.7

sources: ZDI: ZDI-24-173 // JVNDB: JVNDB-2024-002576 // NVD: CVE-2024-23796

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-017796.html

Trust: 2.5

url:https://jvn.jp/vu/jvnvu91198149/

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2024-23796

Trust: 0.8

url:https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-07

Trust: 0.8

sources: ZDI: ZDI-24-173 // JVNDB: JVNDB-2024-002576 // NVD: CVE-2024-23796

CREDITS

Anonymous

Trust: 0.7

sources: ZDI: ZDI-24-173

SOURCES

db:ZDIid:ZDI-24-173
db:JVNDBid:JVNDB-2024-002576
db:NVDid:CVE-2024-23796

LAST UPDATE DATE

2024-08-14T13:16:53.089000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-24-173date:2024-07-01T00:00:00
db:JVNDBid:JVNDB-2024-002576date:2024-02-19T07:09:00
db:NVDid:CVE-2024-23796date:2024-02-13T19:21:35.680

SOURCES RELEASE DATE

db:ZDIid:ZDI-24-173date:2024-02-15T00:00:00
db:JVNDBid:JVNDB-2024-002576date:2024-02-15T00:00:00
db:NVDid:CVE-2024-23796date:2024-02-13T09:15:47.737