ID

VAR-202404-0164


CVE

CVE-2024-3874


TITLE

Tenda W20E Stack Buffer Overflow Vulnerability

Trust: 0.6

sources: CNVD: CNVD-2024-18609

DESCRIPTION

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W20E is a wireless router developed by Tenda, mainly used to provide wireless network connection and management functions. Attackers can exploit this vulnerability to execute arbitrary code

Trust: 1.44

sources: NVD: CVE-2024-3874 // CNVD: CNVD-2024-18609

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-18609

AFFECTED PRODUCTS

vendor:tendamodel:w20escope:eqversion:15.11.0.6

Trust: 0.6

sources: CNVD: CNVD-2024-18609

CVSS

SEVERITY

CVSSV2

CVSSV3

cna@vuldb.com: CVE-2024-3874
value: HIGH

Trust: 1.0

CNVD: CNVD-2024-18609
value: HIGH

Trust: 0.6

cna@vuldb.com:
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: FALSE
obtainAllPrivilege: FALSE
obtainUserPrivilege: FALSE
obtainOtherPrivilege: FALSE
userInteractionRequired: FALSE
version: 2.0

Trust: 1.0

CNVD: CNVD-2024-18609
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

cna@vuldb.com:
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 5.9
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2024-18609 // NVD: CVE-2024-3874

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2024-3874

EXTERNAL IDS

db:NVDid:CVE-2024-3874

Trust: 1.6

db:VULDBid:260908

Trust: 1.6

db:CNVDid:CNVD-2024-18609

Trust: 0.6

sources: CNVD: CNVD-2024-18609 // NVD: CVE-2024-3874

REFERENCES

url:https://vuldb.com/?id.260908

Trust: 1.6

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w20e/formsetremotewebmanage.md

Trust: 1.0

url:https://vuldb.com/?ctiid.260908

Trust: 1.0

url:https://vuldb.com/?submit.312816

Trust: 1.0

sources: CNVD: CNVD-2024-18609 // NVD: CVE-2024-3874

SOURCES

db:CNVDid:CNVD-2024-18609
db:NVDid:CVE-2024-3874

LAST UPDATE DATE

2024-04-20T23:02:13.455000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-18609date:2024-04-19T00:00:00
db:NVDid:CVE-2024-3874date:2024-04-17T12:48:31.863

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-18609date:2024-04-19T00:00:00
db:NVDid:CVE-2024-3874date:2024-04-16T16:15:09.240