ID

VAR-202404-0181


CVE

CVE-2024-3880


TITLE

Tenda W30E Command Injection Vulnerability

Trust: 0.6

sources: CNVD: CNVD-2024-20265

DESCRIPTION

A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router device that provides Internet access, wireless coverage and other functions. In the 1.0.1.25(633) version of Tenda W30E, the formWriteFacMac function of the /goform/WriteFacMac file has a command injection vulnerability, which can be exploited by attackers to execute arbitrary commands

Trust: 1.44

sources: NVD: CVE-2024-3880 // CNVD: CNVD-2024-20265

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-20265

AFFECTED PRODUCTS

vendor:tendamodel:w30escope:eqversion:1.0.1.25(633)

Trust: 0.6

sources: CNVD: CNVD-2024-20265

CVSS

SEVERITY

CVSSV2

CVSSV3

cna@vuldb.com: CVE-2024-3880
value: MEDIUM

Trust: 1.0

CNVD: CNVD-2024-20265
value: MEDIUM

Trust: 0.6

cna@vuldb.com:
severity: MEDIUM
baseScore: 6.5
vectorString: AV:N/AC:L/AU:S/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 8.0
impactScore: 6.4
acInsufInfo: FALSE
obtainAllPrivilege: FALSE
obtainUserPrivilege: FALSE
obtainOtherPrivilege: FALSE
userInteractionRequired: FALSE
version: 2.0

Trust: 1.0

CNVD: CNVD-2024-20265
severity: MEDIUM
baseScore: 6.5
vectorString: AV:N/AC:L/AU:S/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 8.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

cna@vuldb.com:
baseSeverity: MEDIUM
baseScore: 6.3
vectorString: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: LOW
integrityImpact: LOW
availabilityImpact: LOW
exploitabilityScore: 2.8
impactScore: 3.4
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2024-20265 // NVD: CVE-2024-3880

PROBLEMTYPE DATA

problemtype:CWE-78

Trust: 1.0

sources: NVD: CVE-2024-3880

EXTERNAL IDS

db:NVDid:CVE-2024-3880

Trust: 1.6

db:VULDBid:260914

Trust: 1.0

db:CNVDid:CNVD-2024-20265

Trust: 0.6

sources: CNVD: CNVD-2024-20265 // NVD: CVE-2024-3880

REFERENCES

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formwritefacmac.md

Trust: 1.0

url:https://vuldb.com/?ctiid.260914

Trust: 1.0

url:https://vuldb.com/?id.260914

Trust: 1.0

url:https://vuldb.com/?submit.312823

Trust: 1.0

url:https://nvd.nist.gov/vuln/detail/cve-2024-3880

Trust: 0.6

sources: CNVD: CNVD-2024-20265 // NVD: CVE-2024-3880

SOURCES

db:CNVDid:CNVD-2024-20265
db:NVDid:CVE-2024-3880

LAST UPDATE DATE

2024-04-28T22:41:59.596000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-20265date:2024-04-25T00:00:00
db:NVDid:CVE-2024-3880date:2024-04-17T12:48:31.863

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-20265date:2024-04-19T00:00:00
db:NVDid:CVE-2024-3880date:2024-04-16T19:15:08.357