ID

VAR-202404-0347


CVE

CVE-2024-4114


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  tx9 pro  Out-of-bounds write vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2024-017579

DESCRIPTION

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of tx9 pro An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. There is a buffer overflow vulnerability in the Tenda TX9 Pro 22.03.02.10 version. The vulnerability is caused by the time parameter of the sub_42C014 method of the /goform/PowerSaveSet file failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Trust: 2.16

sources: NVD: CVE-2024-4114 // JVNDB: JVNDB-2024-017579 // CNVD: CNVD-2024-23782

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-23782

AFFECTED PRODUCTS

vendor:tendamodel:tx9 proscope:eqversion:22.03.02.10

Trust: 1.6

vendor:tendamodel:tx9 proscope: - version: -

Trust: 0.8

vendor:tendamodel:tx9 proscope:eqversion:tx9 pro firmware 22.03.02.10

Trust: 0.8

vendor:tendamodel:tx9 proscope:eqversion: -

Trust: 0.8

sources: CNVD: CNVD-2024-23782 // JVNDB: JVNDB-2024-017579 // NVD: CVE-2024-4114

CVSS

SEVERITY

CVSSV2

CVSSV3

cna@vuldb.com: CVE-2024-4114
value: HIGH

Trust: 1.0

nvd@nist.gov: CVE-2024-4114
value: HIGH

Trust: 1.0

OTHER: JVNDB-2024-017579
value: HIGH

Trust: 0.8

CNVD: CNVD-2024-23782
value: HIGH

Trust: 0.6

cna@vuldb.com: CVE-2024-4114
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.0

OTHER: JVNDB-2024-017579
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: NONE
impactScore: NONE
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.8

CNVD: CNVD-2024-23782
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

cna@vuldb.com: CVE-2024-4114
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 5.9
version: 3.1

Trust: 2.0

NVD: JVNDB-2024-017579
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2024-23782 // JVNDB: JVNDB-2024-017579 // NVD: CVE-2024-4114 // NVD: CVE-2024-4114

PROBLEMTYPE DATA

problemtype:CWE-787

Trust: 1.0

problemtype:CWE-121

Trust: 1.0

problemtype:Stack-based buffer overflow (CWE-121) [ others ]

Trust: 0.8

problemtype: Out-of-bounds writing (CWE-787) [NVD evaluation ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-017579 // NVD: CVE-2024-4114

PATCH

title:Patch for Tenda TX9 Pro sub_42C014 method buffer overflow vulnerabilityurl:https://www.cnvd.org.cn/patchInfo/show/545736

Trust: 0.6

sources: CNVD: CNVD-2024-23782

EXTERNAL IDS

db:NVDid:CVE-2024-4114

Trust: 3.2

db:VULDBid:261857

Trust: 1.8

db:JVNDBid:JVNDB-2024-017579

Trust: 0.8

db:CNVDid:CNVD-2024-23782

Trust: 0.6

sources: CNVD: CNVD-2024-23782 // JVNDB: JVNDB-2024-017579 // NVD: CVE-2024-4114

REFERENCES

url:https://vuldb.com/?id.261857

Trust: 1.8

url:https://vuldb.com/?submit.317218

Trust: 1.8

url:https://nvd.nist.gov/vuln/detail/cve-2024-4114

Trust: 1.4

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/tx9/setsmartpowermanagement.md

Trust: 1.0

url:https://vuldb.com/?ctiid.261857

Trust: 1.0

sources: CNVD: CNVD-2024-23782 // JVNDB: JVNDB-2024-017579 // NVD: CVE-2024-4114

SOURCES

db:CNVDid:CNVD-2024-23782
db:JVNDBid:JVNDB-2024-017579
db:NVDid:CVE-2024-4114

LAST UPDATE DATE

2025-01-29T23:26:39.839000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-23782date:2024-05-23T00:00:00
db:JVNDBid:JVNDB-2024-017579date:2025-01-28T04:30:00
db:NVDid:CVE-2024-4114date:2025-01-27T16:37:59.997

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-23782date:2024-05-11T00:00:00
db:JVNDBid:JVNDB-2024-017579date:2025-01-28T00:00:00
db:NVDid:CVE-2024-4114date:2024-04-24T15:15:49.107