ID

VAR-202404-2158


CVE

CVE-2024-4240


TITLE

Tenda W9 formQosManageDouble_user function buffer overflow vulnerability

Trust: 0.6

sources: CNVD: CNVD-2024-23281

DESCRIPTION

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W9 is a wireless wall-mounted access point from China's Tenda Company. The vulnerability is caused by the fact that the parameter ssidIndex of the formQosManageDouble_user function fails to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Trust: 1.44

sources: NVD: CVE-2024-4240 // CNVD: CNVD-2024-23281

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-23281

AFFECTED PRODUCTS

vendor:tendamodel:w9scope:eqversion:1.0.0.7(4456)

Trust: 0.6

sources: CNVD: CNVD-2024-23281

CVSS

SEVERITY

CVSSV2

CVSSV3

cna@vuldb.com: CVE-2024-4240
value: HIGH

Trust: 1.0

CNVD: CNVD-2024-23281
value: HIGH

Trust: 0.6

cna@vuldb.com: CVE-2024-4240
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.0

CNVD: CNVD-2024-23281
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:S/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 8.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

cna@vuldb.com: CVE-2024-4240
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 5.9
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2024-23281 // NVD: CVE-2024-4240

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2024-4240

EXTERNAL IDS

db:NVDid:CVE-2024-4240

Trust: 1.6

db:VULDBid:262131

Trust: 1.0

db:CNVDid:CNVD-2024-23281

Trust: 0.6

sources: CNVD: CNVD-2024-23281 // NVD: CVE-2024-4240

REFERENCES

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w9/formqosmanagedouble_auto.md

Trust: 1.0

url:https://vuldb.com/?ctiid.262131

Trust: 1.0

url:https://vuldb.com/?id.262131

Trust: 1.0

url:https://vuldb.com/?submit.319822

Trust: 1.0

url:https://nvd.nist.gov/vuln/detail/cve-2024-4240

Trust: 0.6

sources: CNVD: CNVD-2024-23281 // NVD: CVE-2024-4240

SOURCES

db:CNVDid:CNVD-2024-23281
db:NVDid:CVE-2024-4240

LAST UPDATE DATE

2024-08-14T14:54:12.355000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-23281date:2024-05-17T00:00:00
db:NVDid:CVE-2024-4240date:2024-06-04T19:20:33.263

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-23281date:2024-05-11T00:00:00
db:NVDid:CVE-2024-4240date:2024-04-26T21:15:50.280