ID

VAR-202405-3276


CVE

CVE-2024-35399


TITLE

TOTOLINK CP900L loginAuth function buffer overflow vulnerability

Trust: 0.6

sources: CNVD: CNVD-2024-27554

DESCRIPTION

TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a stack overflow via the password parameter in the function loginAuth. TOTOLINK CP900L is a wireless router from China's TOTOLINK Electronics. There is a buffer overflow vulnerability in the TOTOLINK CP900L v4.1.5cu.798_B20221228 version. The vulnerability is caused by the password parameter of the loginAuth function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

Trust: 1.44

sources: NVD: CVE-2024-35399 // CNVD: CNVD-2024-27554

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-27554

AFFECTED PRODUCTS

vendor:totolinkmodel:cp900l v4.1.5cu.798 b20221228scope: - version: -

Trust: 0.6

sources: CNVD: CNVD-2024-27554

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-35399
value: HIGH

Trust: 1.0

CNVD: CNVD-2024-27554
value: HIGH

Trust: 0.6

CNVD: CNVD-2024-27554
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-35399
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 5.9
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2024-27554 // NVD: CVE-2024-35399

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2024-35399

EXTERNAL IDS

db:NVDid:CVE-2024-35399

Trust: 1.6

db:CNVDid:CNVD-2024-27554

Trust: 0.6

sources: CNVD: CNVD-2024-27554 // NVD: CVE-2024-35399

REFERENCES

url:http://totolink.com

Trust: 1.0

url:https://github.com/s4ndw1ch136/iot-vuln-reports/blob/main/totolink%20cp900l/loginauth/readme.md

Trust: 1.0

url:https://nvd.nist.gov/vuln/detail/cve-2024-35399

Trust: 0.6

sources: CNVD: CNVD-2024-27554 // NVD: CVE-2024-35399

SOURCES

db:CNVDid:CNVD-2024-27554
db:NVDid:CVE-2024-35399

LAST UPDATE DATE

2024-08-14T14:29:49.926000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-27554date:2024-06-18T00:00:00
db:NVDid:CVE-2024-35399date:2024-08-01T13:52:39.410

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-27554date:2024-06-18T00:00:00
db:NVDid:CVE-2024-35399date:2024-05-28T15:15:09.567