ID

VAR-202409-0276


CVE

CVE-2024-41170


TITLE

Siemens Tecnomatix Plant Simulation Stack Buffer Overflow Vulnerability (CNVD-2024-38014)

Trust: 0.6

sources: CNVD: CNVD-2024-38014

DESCRIPTION

A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses the function of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems

Trust: 1.44

sources: NVD: CVE-2024-41170 // CNVD: CNVD-2024-38014

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2024-38014

AFFECTED PRODUCTS

vendor:siemensmodel:tecnomatix plant simulationscope:eqversion:v2302<v2302.0015

Trust: 0.6

vendor:siemensmodel:tecnomatix plant simulationscope:eqversion:v2404<v2404.0004

Trust: 0.6

sources: CNVD: CNVD-2024-38014

CVSS

SEVERITY

CVSSV2

CVSSV3

productcert@siemens.com: CVE-2024-41170
value: HIGH

Trust: 1.0

CNVD: CNVD-2024-38014
value: HIGH

Trust: 0.6

CNVD: CNVD-2024-38014
severity: HIGH
baseScore: 7.2
vectorString: AV:L/AC:L/AU:N/C:C/I:C/A:C
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 3.9
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

productcert@siemens.com: CVE-2024-41170
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2024-38014 // NVD: CVE-2024-41170

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2024-41170

PATCH

title:Patch for Siemens Tecnomatix Plant Simulation Stack Buffer Overflow Vulnerability (CNVD-2024-38014)url:https://www.cnvd.org.cn/patchInfo/show/590316

Trust: 0.6

sources: CNVD: CNVD-2024-38014

EXTERNAL IDS

db:SIEMENSid:SSA-427715

Trust: 1.6

db:NVDid:CVE-2024-41170

Trust: 1.6

db:CNVDid:CNVD-2024-38014

Trust: 0.6

sources: CNVD: CNVD-2024-38014 // NVD: CVE-2024-41170

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-427715.html

Trust: 1.6

sources: CNVD: CNVD-2024-38014 // NVD: CVE-2024-41170

SOURCES

db:CNVDid:CNVD-2024-38014
db:NVDid:CVE-2024-41170

LAST UPDATE DATE

2024-09-13T23:42:26.413000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2024-38014date:2024-09-12T00:00:00
db:NVDid:CVE-2024-41170date:2024-09-10T12:09:50.377

SOURCES RELEASE DATE

db:CNVDid:CNVD-2024-38014date:2024-09-12T00:00:00
db:NVDid:CVE-2024-41170date:2024-09-10T10:15:11.797